WatchTower is sold on its own. A Climate Pros technology, with no Climate Pros service contract required. ← Back to WatchTower ← Back to climatepros.com
EPA leak-detection regulations are now in force (effective January 1, 2026) · systems with 15+ lbs of HFCs require strict leak monitoring Penalties up to $57,000 per day, per violation

EPA AIM Act · Refrigerant compliance

The Leak Rules Are Live.
WatchTower Keeps You Ahead of Them.

Proven leak-detection results from leading retailers. WatchTower’s AI-driven monitoring helps grocers detect refrigerant loss early, document everything the EPA asks for, and avoid the penalties, with a 24/7 triage center behind every alert.

✓ EPA AIM Act ✓ CARB ✓ State regulations ✓ Audit-ready records ✓ SOC 2 Type 2 certified

What the new EPA rules require

The thresholds that now apply to your racks.

Effective January 1, 2026 under the AIM Act. Systems installed 2017 to 2025 must retrofit automatic leak detection by January 1, 2027.

15+ lbs HFCsLeak repair & inspection

Systems with 15 lbs or more of HFCs must meet leak-repair requirements, rate thresholds, and inspection provisions.

1,500+ lbsAutomatic leak detection

Large-charge systems must have Automatic Leak Detection (ALD) installed, from day one on new systems.

Leak-rate limits20% / 30% / 10%

Annual leak-rate caps: 20% for commercial refrigeration, 30% industrial process, 10% comfort cooling.

DocumentationFull audit trail

Complete records of all leaks, repairs, and refrigerant additions, available for EPA audits.

PenaltiesUp to $57,000/day

Per day, per violation, for non-compliance. That cost dwarfs the monitoring that prevents it.

Retrofit deadlineJanuary 1, 2027

Existing systems installed 2017 to 2025 must be retrofitted with ALD by this date.

EPA § 84.108 checklist

How WatchTower meets the ALD requirements.

  • Coverage where required: applies to refrigerant systems over 1,500 lb charge using refrigerants with GWP above 53.
  • Annual audit & calibration: the ALD system is audited and calibrated annually, with records kept.
  • Loss alerts at the threshold: alerts trigger when refrigerant loss exceeds 50 lb or 10% of full charge.
  • Three-year alert log: every date the ALD system triggers is recorded and retained for at least 3 years.

Featured case study

Tailored technology with big results.

One store, one alert, and the documented path from detection to repair. The same records that keep the equipment running are the records an EPA audit asks for.

National grocery retailer

A failing valve, caught before it failed.

Industry: Grocery retail · 600+ locations

Challenge

  • Temperatures fluctuating in a supermarket refrigeration unit.
  • Traditional monitoring often misses fluctuations until they escalate.
  • Undetected drift risks system failure, spoiled product, and off-hours repairs.

Solution

  • WatchTower’s AI platform flagged inconsistent temps with a Case Health Smart Alarm®.
  • A timely evaluation found a malfunctioning EPR valve, cleaned and restored.
  • 24/7 remote monitoring by the triage center confirmed stable recovery.

Results

  • No emergency service calls, no overtime, zero downtime.
  • Valve failure and repair costs avoided; product losses prevented.
  • Energy efficiency restored and equipment lifespan extended.
“WatchTower gave us the visibility and control we needed to get ahead of the new EPA requirements.”
Facilities leader, national grocery retailer

Three full case studies are available on request: request the case study pack.

Take action

The deadline passed.
The retrofit window hasn’t.

New systems need ALD at install; 2017 to 2025 systems must retrofit by January 1, 2027. A free compliance assessment shows exactly where your fleet stands.

Schedule a free assessment